INSTALLATION
WARNING
1. TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
GROUNDING INSTRUCTIONS
2. For the cord-connected rangehood
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit, grounding
reduces the risk of electric shock by providing an escape wire for the electric current.
This appliance is equipped with a cord having a grounding wire with a grounding plug.
The plug must be plugged into an outlet that is properly installed and grounded.
WARNING - Improper grounding can result in a risk of electric shock.
Consult a qualified electrician if the grounding instructions are not completely
understood, or if doubt exists as to whether the appliance is properly grounded.
Do not use an extension cord. If the power supply cord is too short, have a qualified
electrician install an outlet near the appliance
3. For the permanently-connected rangehood
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards, including fire-rated
construction.
B. Sufficient air is needed for proper combustion and exhausting of gases through the
flue (chimney) of fuel burning equipment to prevent back drafting. Follow the
heating equipment manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and
the local code authorities.
C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and
other hidden utilities.
D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be marked as appropriate
for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) –
protected branch circuit.
F. Installation work and electrical wiring must be done by qualified person(s) in
accordance with the National Electrical Code, ANSI/NFPA 70 and local codes.
Before you begin installing, switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
G. Connect power cable to house wiring inside of electrical outlet box. Conductor of
product identified as grounded conductor (WHITE) to be connected to a grounded
conductor (WHITE) of power supply, conductor of product identified as
ungrounded conductor (BLACK) to be connected to an ungrounded conductor
(BLACK) of power supply, conductor of product identified for equipment grounding
(GREEN) to be connected to an equipment grounding (GREEN) conductor. Secure
power cable to wiring box with appropriate wire clamp and re-attach outlet box
cover.