3. INSTALL THE UNIT (CONT’D)
3.7 EXTERIOR OPENING(S) INSTALLATION (CONT’D)
3.7.4 L
OCATING TWO SOFFIT GRILLES
If this unit is installed in the attic, use the installation kit no. EA20130 (not available
in the U.S.A.). Choose an appropriate location for installing the soffit grilles
(included in the installation kit no. EA20130).
WARNING
!
Make sure the air intake grille is at least 6 feet (1.8 m) away (or more, as per
applicable building codes or standards) from sources of contamination
such as:
• High efficiency furnace vent
• Any exhaust from a combustion source
• Gas meter exhaust, gas barbecue-grill
• Garbage bin
• Do not locate where
prevailing winds blow the
stale air towards the fresh
air vent.
• There must be a minimum
distance of 6 feet (1.8 m)
between the grilles to avoid
cross-contamination. See
illustration at right.
VD0160
6’ (1.8
M
)
3.7.5 CONNECTING INSULATED DUCTS TO TWO SOFFIT GRILLES
CAUTION
Make sure the insulated ductwork vapor barrier does not tear during
installation.
2. Using provided screws, attach the
flexible duct to the ring of the soffit
grille. Carefully seal with duct tape.
Assemble the soffit grilles to the soffit.
VI0014
1. For each exterior hole, using a jig
saw, cut a 4¼’’ diameter hole in the
soffit. Pull back the insulation to
expose the flexible duct. Run each
flexible duct through its respective
hole.