SBI-240 Service Manual 35
10.n.DSP NO NO Display weight at 10
times division number
under primary unit
*If (REGULA)= none this
parameter will not be available.
When yes is selected, some
menus will not be active.
YES
MOTiON 1-255 4 Motion window 1-255 = ±0.25d *(1-255)
*If (REGULA)=none, the max is 12
OVER.l.D 0-100 0 Overload display
limitation
0=FS+9d
1-100=101%FS -200%FS.
*If
(REGULA)=none, the max is 10
ad.from adc adc Where the A/D data
comes from
ADC=local A/D chip on PCB
COM3=COM3 interface
com3
ad.hspd no no Speed of A/D conversion NO=10Hz;
YES=80Hz;
if AD.FROM=COM3,this item will
not be shown
yes
UNITS KG yes yes UNITS key YES = enable this unit
No = disable this unit
In trade applications, lb:oz is not
allowed
no
lb yes yes
no
oz yes no
no
lb:oz yes no
no
gyesyes
no
CONFG
SubMenu1 SubMenu2 Option Default Parameter Description Comment