34 SBI-240 Service Manual
PRIM.N 100 -
100000
Primary full scale value Default full scale value will depend
on capacity of scale.
*If (REGULA) none, the max is
10,000
PRIM.D 0.0001 The division value under
primary unit
Default division size will depend on
capacity of scale.
The division value under second
unit is automatically determined by
the indicator according to the
division value under primary unit.
0.0002
0.0005
0. 0 0 1
0. 0 0 2
0. 0 0 5
0. 0 1
0. 0 2
0. 0 5
0. 1
0. 2
0. 5
1
2
5
10
20
50
PRIM.Ut kg Primary
u Select
the primary unit from kg or lb.
The second unit is lb if kg is
selected as the primary unit.
*
The calibration standard weight
must be in the pri
mary unit!
lb
SECnD.N 100-
125000
Second scale full scale
value
The division number under second
unit. The maximum is
1.25*(PRIM.N).
*If (REGULA)
none, the max is
10,000
NOTE: Secondary divisi
on has
to
match the primary divis
ion.
CONFG
SubMenu1 SubMenu2 Option Default Parameter Description Comment