¡ Ensure that the information on the rating plate re-
garding the gas type and gas pressure complies
with the local connection conditions.
¡ Connect the appliance to a fixed gas pipe or a flex-
ible metal pipe.
¡ The flexible metal pipe must not come into contact
with the moving parts of the unit in which the appli-
ance is installed (e.g. a drawer) and must not be
routed through any spaces which might become ob-
structed.
¡ Gas connection on the appliance: G 1/2.
Connection to gas cylinder or liquid gas tank
If the flame is large or unstable, check that the
regulator of the gas cylinder or liquid gas tank is
working properly.
Note:You can install an overpressure safety device
that limits or cuts off the gas supply if the regulator
of the gas cylinder or liquid gas tank fails.
Spare parts for gas connection
If the country's regulations allow, you can obtain the
gas connection parts from the technical customer
service.
→Fig.
9
Gas connection R 1/2
Fit the seal and the connecting piece R 1/2 to the
gas connection on the appliance.
→Fig.
10
Gas connection G 1/2
Insert the seal between the gas connection of the
appliance and the gas supply.
→Fig.
11
Electrical connection
¡ This appliance is type Y: The connection cable must
only be replaced by technical customer service and
not by the user. The cable type and the minimum
cross section must be respected.
¡ The hobs are supplied with a power cord with or
without a plug.
¡ The power cable must only be replaced with a cable
from the original manufacturer. This is available
from after-sales service.
¡ Do not use extension cables or multiple socket
strips.
¡ Only connect appliances that are fitted with a plug to
a correctly installed socket with protective earth con-
ductor.
¡ Connect the appliance to a fixed installation and set
up appropriate isolating switches in accordance with
the installation regulations.
→Fig.
12
¡ BN: Brown
¡ BU: Blue
¡ GN/YE: Green and yellow
Converting the gas type
If the country's regulations allow, this appliance can
be adapted to other types of gas, if these are listed
on the rating plate.
You can find the right parts in the bag that is sup-
plied with the appliance or you can obtain them from
customer service. The table shows the right combin-
ation for the relevant burner and gas type.
Standard-output burner
High-output burner
Adjusting the taps
1. Set the control elements to the minimum power
level and pull them out.
2. To access the bypass screw, use the tip of the
screwdriver to push down on the flexible rubber
holder.
→Fig.
13
Never remove the sealing ring. Sealing rings pre-
vent liquids and dirt from finding their way into the
appliance and impairing its ability to function prop-
erly.
3. When adjusting the bypass screws (M), refer to
the table →Fig. .
A: Firmly tighten the bypass screws.
B: The bypass screws must be flush with the fit-
ting.
→Fig.
14
Replacing the nozzles
1. Remove all pan supports, burner caps and distrib-
utors.
2. Replace the nozzles using the appropriate wrench
and tighten them carefully to guarantee the seal.
→Fig.
15
Ensure that the nozzle does not become detached
during removal or fastening.
Reinstalling the appliance
Install the appliance components in reverse order.
Checking if equipment is working
1. Check that turning the rotary knob between the
position for maximum power and the position for
minimum power does not cause the burner to go
out or result in backfire.
2. If the gas flow from the burner is not correct, in
the table →Fig. , check whether the nozzle and
the position of the bypass screw are correct.
Documenting the gas type conversion
Attach the sticker showing the new gas type near
to the rating plate.
es
Montaje seguro
Tener en cuenta estas indicaciones de seguridad al
montar el aparato.
¡ Lea atentamente estas instrucciones.
¡ Las imágenes representadas en estas instruccio-
nes tienen carácter orientativo.
¡ Solamente un montaje profesional conforme a las
instrucciones de montaje puede garantizar un uso
seguro del aparato. El instalador es responsable
del funcionamiento perfecto en el lugar de instala-
ción.
¡ Después de realizar la conexión, efectuar una
prueba de estanqueidad.
ADVERTENCIA‒Riesgo de explosión!
Un escape de gas puede provocar una explosión.
Todos los trabajos de instalación, conexión, regu-
lación y adaptación a otro tipo de gas deben ser
realizados por un técnico especialista autorizado y
de conformidad con los reglamentos y disposicio-
nes legales vigentes y los reglamentos de las
compañías locales suministradoras de electrici-
dad y gas. Debe prestarse especial atención a la
normativa aplicable a la ventilación. Para los tra-
bajos de adaptación a otro tipo de gas, recomen-
damos ponerse en contacto con el Servicio de
Atención al Cliente.