Bosch GCL 12V-50-22 CG Professional handleiding

717 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 49 van 717
English | 49
Place the measuring tool 2.5m away from the door opening on a firm, flat surface (not
on a tripod). Switch on the measuring tool and select vertical line mode. Aim the laser
line at the door opening and allow the measuring tool to level in.
2,5 m
2,5 m
Mark the centre of the vertical laser line
on the floor of the door opening
(point), 5m away on the other side of
the door opening (point) and on the
upper edge of the door opening
(point).
d
2 m
Rotate the measuring tool 180° and pos-
ition it on the other side of the door
opening, directly behind point. Allow
the measuring tool to level in and align
the vertical laser line in such a way that
its centre passes through points and
exactly.
Mark the centre of the laser line on the upper edge of the door opening as point.
The discrepancy d between the two marked points and reveals the actual ver-
tical deviation of the measuring tool.
Measure the height of the door opening.
You can calculate the maximum permitted deviation as follows:
Doubled height of the door opening×0.3mm/m
Example: At a door opening height of 2m, the maximum deviation amounts to
2×2m×±0.3mm/m=±1.2mm. The points and must therefore be no further
than 1.2mm from each other.
Checking Plumb Accuracy
For this check, you will need a clear measuring space on firm ground with a distance of
approx. 5m between the floor and the ceiling.