Appliance description
EN
bora.com 21
*only applies to the front cooking zone
3.4
Safety features
3.4.1
Safety shut-down
If the appliance is switched on but not used for 2 minutes, it will
automatically switch off (standby mode).
Cooktop extractor
The cooktop extractor will be automatically switched off 30 minutes
after all cooking zones have become inactive (= power level 0) and
the automatic after-run function will be started.
Cooktops
Each cooking zone is automatically switched off after a predefined
operating time in which the power level has not been changed.
Power levels Safety shut-down after hrs:min
CKFI, CKI,
CKIW, CKT
CKCH, CKCB CKG
8:24 6:00 8:24
6:24 6:00 6:24
5:12 5:00 5:12
4:12 5:00 4:12
3:18 4:00 3:18
2:12 1:30 2:12
2:12 1:30 2:12
1:48 1:30 1:48
1:18 1:30 1:18
8:00 8:00 8:00
8:00 8:00 8:00
8:00 8:00 8:00
Tab.3.18
Safety shut-down on the different power levels
u
Switch the cooking zone back on if you want to put the cooking
zone back into operation
3.4.2
Residual heat indicator
If a cooking or grilling zone is still hot after switching off, there is a
risk of burns or fire. Whilst the Hot symbols and are displayed
(residual heat indicator), you must not touch that cooking or grilling
zone or place any heat-sensitive objects on it. After a sufficient
cooling period (<50°C) the indicators will go out.
During or after a power cut, the cooktops may still be hot. In
the case of the Hyper, HiLight and gas cooktops, no residual
heat is displayed after a power cut, even if they were in use
beforehand and the rings are still hot.
3.4.3
Overheating protection
The appliance is fitted with overheating protection. The overheating
protection can be triggered if:
T
cookware is heated up empty;
T
oil or fat is heated on high power;
T
a hot cooking zone is switched on again after a power cut.
Whilst the overheating protection is active, one of the following steps
is taken:
T
the activated power setting is switched back to the previous level;
T
the power setting can no longer be switched on;
T
the set power level is reduced;
T
the cooktop switches off completely.
After a sufficient cooling period, the cooktop can be used again in
full.
If the operating panel overheats, cooktops or the whole
system may be switched off.
3.4.4
Child lock
The child lock prevents the appliance from being switched on
accidentally.