SAFETY & IMPORTANT INFORMATION
Warning
WARNING INFORMATION REGARDING APPLIANCES WITH R290 REFRIGERANT GAS
Thoroughly read all the warnings.
This appliance contains up to 260gm of R290 refrigerant gas.
This appliance uses R290 refrigerant, which is class 3 ammability and must be handled by a
refrigeration mechanic with appropriate Australian full refrigerant handling license.
The appliance must be installed, used and stored in a ventilated area with the below specified area
PRC6000026 Optima Portable Room Air Conditioner 2.6KW must be stored in an area more than 7.7 m2
When cleaning the appliance, do not use any tools other than those recommended by the
manufacturing company
DO NOT
use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer. The appliance must be placed in an area without any
continuous sources of ignition (for example: open flames, gas or electrical appliances in operation).
DO NOT
puncture and
DO NOT
burn, Refrigerant gases can be odorless.
If the appliance is installed, operated or stored in a non-ventilated area, the room must be
designed to prevent the accumulation of refrigerant leaks resulting in a risk of re or explosion
due to ignition of the refrigerant caused by electric heaters, stoves, or other sources of ignition.
Compliance with national gas regulations shall be observed. Keep ventilation openings clear of
obstruction. A warning that the appliance shall be stored in a well-ventilated area where the room
size corresponds to the room area as specified for operation.
Any person who is involved with working on or breaking into a refrigerant circuit should hold a
current valid certificate from an industry-accredited assessment authority, which authorizes their
competence to handle refrigerants safely in accordance with an industry recognized assessment
specification.
Servicing shall only be performed as recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel shall be carried out
under the supervision of the person competent in the use of flammable refrigerants.
The appliance
MUST BE
stored in such a way as to prevent mechanical failure.
Repairs must be performed based on the recommendations from the manufacturing company.
Maintenance and repairs that require the assistance of other qualified personnel must be performed
under the supervision of an ndividual specified in the use of flammable refrigerants.
MANDATORY INSPECTION PRIOR TO INSTALLATION
Immediately report any damage or discrepancies to the Supplier of the appliance. This appliance was
inspected and tested at the time of manufacture and packaging and released for transportation
without known damage. Upon receipt, inspect the exterior for evidence of rough handling in shipment.
Ensure that the appliance is labelled correctly for the gas and electrical supply, and/or other services
it is intended to be connected for safety and warranty purposes, appliances that may be damaged or
incorrect MUST NOT be installed or operated under any circumstances. Installation of damaged or
incorrect appliances may contravene local government regulations. Bonaire disclaims any liability or
responsibility whatsoever in relation to the installation or operation of damaged or
incorrect appliances.