Adjusting Outputs
Selecting Outputs allows you to enable and adjust the volume levels for speaker and line
outputs.
Table 12. Limiter Settings
Threshold Sets the signal level at which the limiter is triggered. Any
signal exceeding this threshold will be compressed to this
level.
The range is
24 to +24 dB.
Decay Sets the rate for turn off of the limiter after the signal is
below the threshold.
Decay range is 5 to 2300 milliseconds.
RMSTC
(Root Mean Square
Time Constant)
Sets how fast the limiter reacts to a signal that has
exceeded the threshold.
RMSTC range is 50 to 10000 dB/sec.