RS-232 Configuration and Telnet Commands
COMMAND ACTION
? / HELP Print help information
STATUS Print system status and port status
ELESTA Print All Outputs Electricity Level Information
FWVERSION Print FW Version And GUI Version
DEVICENAME:xx Set Device Name To xx
PON Set System Power to ON
POFF Set System Power to OFF
RELAY ON/OFF Set System RELAY Control ON Or OFF
KEY ON/OFF Set System Key Control ON Or OFF
RESET
Reset System To Default Setting(Type “Yes” To Con-
firm, “No” To Discard)
REBOOT Set System Reboot And Apply New Config!!!
RESTA Set System Restart
SETCURRENTHRESH-
OLD xx
Set System Current Threshold To xx (xx to one
decimal place at most)
xx = 0.0 : 10.9
SAFEMODE xx
Set The System Safe Mode To xx When Overloaded
xx = 0 Outlet_Shutdown
1 System_Shutdown
2 Auto_Retry
OVERLOADRETRYCNT
xx
Set The System Retry Number To xx When
Overloaded(Default: 1) xx = 1 : 3
OVERLOADRETRY-
TIME xx
Reset System To Default Setting
STANDBYMODE xx
Set The System Standby Mode To xx
xx = 0 All_Standby_Mode
1 Sleep_Mode
RELAYMODE xx
Set The System Relay Mode To xx
xx = 0 Dry_Contact
1 Push_Button
RELAYVOLTAGE xx
Set The System Relay Toggle Voltage To xx
xx = 0 Low_Voltage
1 High_Voltage
BEEPERTIME xx
Set The Buzzer Sound Time To xx Seconds When
Alarming (Default: 10 Seconds)
xx = 0 : 9999
OUTLETTIMEON xx:yy
Set Outlet xx Power_ON Delay To yy Seconds
xx = 1 Outlet 1
2 Outlet 2
3 Outlet 3
4 Outlet 4
yy = 0 : 9999
OUTLETTIMEOFF xx:yy
Set Outlet xx Power_OFF Delay To yy Seconds
xx = 1 Outlet 1
2 Outlet 2
3 Outlet 3
4 Outlet 4
yy = 0 : 9999
OUTLETELERESET
xx:yy
Set Outlet xx Electrical Work Reset Duration To yy
Seconds (Default: 10 Seconds)
xx = 1 Outlet 1
2 Outlet 2
3 Outlet 3
4 Outlet 4
yy = 0 : 9999
ALLOUT ON/OFF Set All Outlets ON/OFF
COMMAND ACTION
OUTLET xx ON/OFF
Set Outlet xx ON/OFF
xx = 1 Outlet 1
2 Outlet 2
3 Outlet 3
4 Outlet 4
RSALLOUTELE Clean Up All Outlets Electrical Work
RSOUTELE xx
Clean Up The Outlet xx Electrical Work
xx = 1 Outlet 1
2 Outlet 2
3 Outlet 3
4 Outlet 4
SYSTIME Get The Time For The System
RESYSTIME yyyy-mm-
dd;hh:mm:ss
Set The Time For The System
yyyy = Year
mm = Month
dd = Day
hh = Hour
mm = Minute
ss = Second
RS232OUT y:z:c:a
Send y Type Of Command a With Baud Rate z, Parity
c To Output
y=a: ASCII
y=h: HEX
z=1: 2400
z=2: 4800
z=3: 9600
z=4: 19200
z=5: 38400
z=6: 57600(Default)
z=7: 115200
c=1: None
c=2: Even
c=3: Odd
a=RS232 Command
RS232BAUD z
Set RS232 Baud Rate To xx
z = 1 - 2400
2 - 4800
3 - 9600
4 - 19200
5 - 38400
6 - 57600(Default)
7 - 115200
NET TCP/IP ENABLE xx
Set TCP/IP xx Enable(Only One Can Be Enabled)
xx = 1 TCP/IP1
2 TCP/IP2
NET TCP/IP1 DHCP
ON/OFF
Set TCP/IP1 Auto IP (DHCP) ON or OFF
NET TCP/IP1 IP xxx.
xxx.xxx.xxx
Set TCP/IP1 IP Address
NET TCP/IP1 GW xxx.
xxx.xxx.xxx
Set TCP/IP1 Gateway Address
NET TCP/IP1 SM xxx.
xxx.xxx.xxx
Set TCP/IP1 Subnet Mask Address
NET TCP/IP2 DHCP
ON/OFF
Set TCP/IP2 Auto IP (DHCP) ON or OFF
NET TCP/IP2 IP xxx.
xxx.xxx.xxx
Set TCP/IP2 IP Address
NET TCP/IP2 GW xxx.
xxx.xxx.xxx