Blustream PWR4IEC handleiding
Handleiding
Je bekijkt pagina 42 van 49

PWR4IEC USER MANUAL
www.blustream.com.au | www.blustream-us.com | www.blustream.co.uk42
RS-232 Configuration and Telnet Commands
The PWR4IEC can be controlled via serial and TCP/IP.
The default RS-232 communication settings are:
Baud rate: 57600
Data bit: 8
Stop bit: 1
Parity bit: none
The following pages list all available serial / IP commands.
Commonly used Serial Commands
There are several commands that are commonly used for control and testing:
STATUS Status will give feedback on the unit such as outputs on, type of connection etc...
PON Power on
POFF Power o
RELAY ON/OFF Toggling the relay input / output control ON or OFF as required
Example:- RELAYON (This would turn the ability for the relays to trigger events on)
OUTLET xx ON (xx is the outlet)
Example:- OUTLET04ON (This would switch outlet 4 to ON)
Common Mistakes
• Carriage return – Some programs do not require the carriage return where as other will not work unless sent
directly aer the string. In the case of some Terminal soware the token <CR> is used to execute a carriage return.
Depending on the program you are using this token maybe dierent. Some other examples that other control systems
deploy include \r or 0D (in hex)
• Spaces – Blustream commands do not require space between commands unless specified. There may be some
programs that require spacing in order to work.
- How the string should look is as follows OUTLET04ON
- How the string may look if spaces are required: OUTLET{Space}04{Space}ON
• Baud rate or other serial protocol settings not correct
Bekijk gratis de handleiding van Blustream PWR4IEC, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Blustream |
| Model | PWR4IEC |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 8395 MB |

