PWR4IEC USER MANUAL
www.blustream.com.au | www.blustream-us.com | www.blustream.co.uk42
RS-232 Configuration and Telnet Commands
The PWR4IEC can be controlled via serial and TCP/IP.
The default RS-232 communication settings are:
Baud rate: 57600
Data bit: 8
Stop bit: 1
Parity bit: none
The following pages list all available serial / IP commands.
Commonly used Serial Commands
There are several commands that are commonly used for control and testing:
STATUS Status will give feedback on the unit such as outputs on, type of connection etc...
PON Power on
POFF Power o
RELAY ON/OFF Toggling the relay input / output control ON or OFF as required
Example:- RELAYON (This would turn the ability for the relays to trigger events on)
OUTLET xx ON (xx is the outlet)
Example:- OUTLET04ON (This would switch outlet 4 to ON)
Common Mistakes
Carriage return – Some programs do not require the carriage return where as other will not work unless sent
directly aer the string. In the case of some Terminal soware the token <CR> is used to execute a carriage return.
Depending on the program you are using this token maybe dierent. Some other examples that other control systems
deploy include \r or 0D (in hex)
Spaces – Blustream commands do not require space between commands unless specified. There may be some
programs that require spacing in order to work.
- How the string should look is as follows OUTLET04ON
- How the string may look if spaces are required: OUTLET{Space}04{Space}ON
Baud rate or other serial protocol settings not correct