Fault Symptom Reason Solution
Restart the unit. If the symptom persists, please
contact BLUETTI support for assistance.
1. Wait for 5 minutes. If the D40 resumes operation
after cooling down, it suggests inadequate
ventilation in the current location.
2. Power off the D40 and any related devices.
3. Disconnect all cables and remove the D40.
4. Move the D40 to a suitable location. If the
symptom persists, please contact BLUETTI support
for assistance.
Charging
indicator off;
Alarm indicator
on;
Battery indicator
blinks slowly (@
approx. 3Hz).
Output
Overvoltage
Protection
When the unit's
temperature
reaches 70°C /
158°F, the fan
automatically
activates; when it
reaches 102°C /
215.6°F, the
temperature
protection will be
triggered.
Charging
indicator off;
Alarm indicator
blinks slowly (@
approx. 1.5Hz).
Temperature
Protection
Please check whether the output connection is a
battery, if so, please replace it with a load
connection in time.
Charging
indicator blinks
slowly (@ approx.
1.0Hz).
Battery
Connection
Protection
/
1. Reduce the load if necessary.
2. Check that the Anderson connector is connected
to the DC OUTPUT terminal with the correct
polarity.
3. Fix the connections, and check if the D40
functions properly.
4. Restart the unit. If the symptom persists, please
contact BLUETTI support for assistance.
Alarm indicator
steady
Reverse
Polarity
Protection
(Output) /
Overcurrent
Protection
Load Mode