Chapter 7: Console Commands
SET MONITOROKCOUNT [N]
GET MONITOROKCOUNT
Set or display the number of successive PING attempts that must succeed before the A/B Switch automatically
switches back to the normal path and removes the alternate connection path. The valid range is 1 to 255. A
value of 0 disables only the automatic recovery function – automatic switching will still operate if enabled. If auto
recovery is disabled the user must manually switch back to the normal path via the front panel toggle switch or
by issuing a “set system B” command. Any change will not become permanent until a SAVE operation is
performed.
SET AUTHENTICATIONTRAP ON[OFF]
GET AUTHENTICATIONTRAP
Set or display the current state of authentication error traps. Authentication traps will be generated when this
parameter is set to ON, and not when OFF. Note that this setting only affects the trap generation, and not how
the network module handles an authentication failure. An authentication failure generally means that an SNMP
access was attempted with an incorrect community name. Any change will not become permanent until a
SAVE and RESET operation sequence is performed.
SET ALERTTYPE [TRAP/SYSLOG]
GET ALERTTYPE
Set or display the type of alert messages sent by the A/B Switch when certain events such as a change in switch
state occur. The A/B Switch can be configured to issue either syslog messages, or SNMP traps.
NOTE: At least one IP address must be entered using the “SET MANAGER N X.X.X.X” command before either
syslog messages or traps will be issued. See Section 9 for a list of the traps supported by the A/B Switch,
and see section 10 for a list of the supported syslog messages.
SET ADMINIP N X.X.X.X
Set administrator N (1-8) IP address. Up to 8 different administrator IP addresses can be entered. To remove an
entry from the list, set the IP address to 0.0.0.0. If all 8 ADMIN IP addresses are 0.0.0.0 (no ADMIN IP addresses
are configured) the A/B Switch will allow access via the Ethernet interface from any IP address, subject to the
existing password and enable flags for each interface. If one or more ADMIN IP addresses are non-zero, the A/B
Switch will only process messages received from the configured (non-zero) ADMIN IP addresses. All other
messages will be ignored. This ADMIN IP address filtering feature applies to the telnet, web browser and SNMP
Ethernet interfaces and to the PING reply functions. The ADMIN IP address filtering does not affect outgoing
PING and ARP messages so the A/B Switch is still able to monitor any IP address for the “auto-switch” features.
The administrator IP addresses can be different than the manager IP addresses. Any change will not become
permanent until a SAVE operation is performed.
GET ADMINIP N
Display the IP address of administrator N (1-8). If no value is entered for “N”, then all administrator IP addresses
will be displayed.
ADMIN IP Addresses:
1: 192.168.1.113
2: 192.168.1.115
3: 192.168.1.149

Bekijk gratis de handleiding van Black Box SW1046A, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkBlack Box
ModelSW1046A
CategorieNiet gecategoriseerd
TaalNederlands
Grootte3336 MB

Caratteristiche Prodotto

Kleur van het productZwart
Gewicht1800 g
Breedte159 mm
Diepte205.7 mm
Hoogte64 mm