CALIBRATION
HG-2
CALIBRATION
Guide / Instructions
Sets the overall input level of the HG-2 for proper gain staging as well as left / right balance.
1: Set the HG-2 so that the Pentode and Triode are at 12 o'clock, output is set as shown below. Make
sure ‘air’ and Saturation are off.
Step 1: Input Calibration
2: Send the output of the signal generator (or DAW) into the HG-2 and feed the output of the HG-2
to the meters.
3: Send a 1khz, -20 signal to the HG-2. The exact level is not important as long as it is not driving
the unit into saturation.
4: Put the HG-2 into bypass and note the reading on your meters (not on the HG-2)
5: Disengage bypass and note the meter reading. Adjust the input trimmers (see below) as needed until
the reading matches the reading in bypass mode. When the meter reading is the same in bypass and
active states, the HG-2 is input gain is calibrated properly.
Left input trim
Right input trim
REAR