GENERAL INFORMATION
If you wish to return to the previous selection menu, press the MENU button.
By pressing and holding the ENTER button, you can skip individual setting
steps and start stimulation treatment straight away.
Button lock
Locks the buttons to avoid them being pressed unintentionally.
1.
To activate the button lock, hold down the ENTER button for approx.
3seconds, until the symbol is visible in the display.
2. To deactivate the button lock, hold down the ENTER button again for ap-
prox. 3 seconds, until the
symbol disappears from the display.
Pausing use
You can pause the stimulation at any time by briefly pressing the ON/OFF
button
. To continue the stimulation, set your preferred pulse intensity
again.
9. HEAT
In addition to the TENS/EMS/Massage programs, the EM89 Heat also oers
two heat levels which can be activated as required for all programs, see “Start-
ing use” section. The heat supplied via the gel pads relaxes the muscle and
improves circulation. You can activate the first level of the heat function by
pressing the Heat button. Then wait a moment until the temperature stops in-
creasing. If the temperature is too low for you, you can activate the second
level of the heat function by pressing the Heat button again. If you would like to
deactivate the heat function, you can do so by pressing the Heat button again.
If you want to use the heat function separately, without additional stimulation,
proceed as follows:
Step 1: Position the electrodes in your preferred target area. (See “Informa-
tion on electrode positioning” section for positioning suggestions) and connect
them to the device. To use the heat function, always apply both electrodes of
the channel being used. The channels used are shown on the display.
Step 2: Press and hold the ON/OFF button for at least one second to switch
on the device.
Step 3: Press the Heat button to access heat function adjustment.
Step 4: Use the / adjustment buttons to select your preferred treatment
time and press the ENTER button to confirm your selection.
Step 5: The first level of the heat function is set, and the symbol lights
up. Then wait a moment until the temperature stops increasing. If the temper-
ature is too low for you, you can activate the second level of the heat function
by pressing the Heat button again. The symbol appears. Pressing the
Heat button again switches the device back to the lower heat level ( ).
To use the heat function, always apply both electrodes of the channel
being used. The channels used are shown on the display.
10. PROGRAM OVERVIEW
The Digital TENS/EMS device features a total of over 70 programs:
• 15 TENS programs
• 35 EMS programs
• 20 MASSAGE programs
In all of the programs you can set the pulse intensity of the four channels in-
dividually.
You can also set various parameters in TENS programs 13-15 and EMS pro-
grams 33-35 to adjust the stimulating eect to the application area.
10.1 TENS program table
Prog.
no.
Eective application areas, indications Running
time
(min)
Possible
electrode
positioning
1 Pain in upper limbs 1 30 12–17
2 Pain in upper limbs 2 30 12–17
3 Pain in lower limbs 30 23–27
4 Ankle pain 30 28
5 Shoulder pain 30 1–4
6 Pain in the back 30 4–11
7 Pain in buttocks and back of thighs 30 22, 23
8 Pain relief 1 30 1–28
9 Pain relief 2 30 1–28