Beurer EM 89 handleiding
Handleiding
Je bekijkt pagina 30 van 228

30
19
Pulse intensity, channel 2
20
Pulse intensity, channel 3
Ch3
21
Pulse intensity, channel 4
Ch4
7. INITIAL USE
You must fully charge the EM 89 Heat before you use it for the first time. To do
so, proceed as follows:
1. Connect the USB charging cable to a suitable mains adapter (output volt-
age max. 5V/2A), see “Replacement parts and wearing parts” section and
the EM89 Heat (mains adapter not included, available as a servicing item).
2.
Then insert the mains adapter into a suitable socket. You cannot use the
device while it is being charged.
3. Do not pull, twist or sharply bend the cables
B 2
.
4. After the charging process is complete, apply the provided gel pads to the
electrodes. To do this, carefully remove one of the protective films
B 3
.
5. Carefully attach the gel pad to the electrode and gently peel o the protec-
tive film
B 4
. Ensure that the edge of the gel pad does not protrude over
the electrode. Applying gel pads slightly askew will not aect their function.
WARNING!
Peel o the protective film slowly and carefully. Make sure that the self-adhe-
sive gel pad is not damaged, as damage or unevenness on the gel pad may
cause skin irritation.
8. HOW TO USE
8.1 Starting use
Step 1: Find a suitable program in the program tables (see “Program overview”
section).
Step 2: Place the electrodes on your target area (for positioning suggestions,
see page 5 “Information on electrode positioning”) and connect them to the
device.
Step 3: Hold the ON/OFF button
pressed for at least one second to switch
on the device.
Step 4: Press the MENU button to navigate through the / /
menus and confirm your choice by pressing the ENTER button.
Step 5: Use the / adjustment buttons to select the program number you
want and press the ENTER button to confirm your selection. At the start of the
stimulation treatment, the pulse intensity of / /
Ch3
and
Ch4
is set
to “00” by default. No pulses are sent to the electrodes yet.
Step 6: Use the / intensity adjustment buttons on the right-hand side as rel-
evant for / /
Ch3
and
Ch4
to select your preferred pulse intensity.
The indicator for pulse intensity in the display changes accordingly. The grey
electrodes belong to channels 1 and 3, the red electrodes to channels 2 and 4.
Step 7: You can activate the heat function using the Heat button. The first press
of the button activates the low heat level, the second button press activates
the high heat level, and the third button press deactivates the heat function.
8.2 Notes on use
• After 30 seconds of inactivity, the device’s illuminated display switches o
automatically. You can reactivate it by pressing any button (except the ON/
OFF button
).
• The device switches itself o automatically if you do not use it for one min-
ute (automatic switch-o). When switched on again, the LCD screen of the
menu selection appears with the most recently used menu flashing.
• A brief acoustic signal is output when a valid button is pressed. Two brief
acoustic signals are output when an invalid button is pressed.
• You can pause the stimulation at any time by briefly pressing the ON/OFF
button
. To continue the stimulation, set your preferred pulse intensity
again.
Bekijk gratis de handleiding van Beurer EM 89, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Beurer |
| Model | EM 89 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 23250 MB |