IX. SERVICE
Figure 10 - Bottom Access Panel
SCREWS
A. PERFORMING PREVENTIVE MAINTENANCE
1. Disconnect the power to the unit.
2. Filter - the aluminum washable lter is held in by the
inlet screen. Access the lter from the top of the unit
by removing the Phillips head screws that attach the
screen. Vacuum and/or wash with dish soap and water.
3. Internal - open the bottom access panel by
removing the Phillips head screws on the top front of
the unit. Vacuum and scrape (if necessary)
to remove the build-up of dirt and debris. The motor(s)
are permanently lubricated and require no additional
lubrication.
4. Re-install the bottom access panel and intake screen.
See Figure 10.
5. Reconnect the power after cleaning.
CAUTION: STAND CLEAR OF THE UNIT OR WEAR SAFETY
GOGGLES AS LOOSE DEBRIS MAY BE PRESENT AND MAY EXIT
THE NOZZLE UPON START UP!
CAUTION: ELECTRIC SHOCK HAZARD Disconnect power
whenever servicing unit. More than one disconnect may
be required to de-energize unit.
Any service performed on the Architectural Elite Series air curtain
MUST be done by qualied personnel. Berner air curtains require
very little servicing. All parts are easily accessible for periodic
inspection and maintenance.