Handleiding
Je bekijkt pagina 20 van 59

1. When charging refrigerant into the system, make sure to
charge in liquid state,if therefrigerant of the appliance is
R32. Otherwise, chemical composition of refrigerant (R32)
inside the system may change and thus affect performance
of the air conditioner.
2. According to the character of refrigerant (R32,the value of
GWP is 675), the pressure of the tube is very high, so be
sure to be careful when you install and repair the appliance.
3. If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
4. Installation of this product must be done by experienced
service technicians professional installers only in
accordance with this manual.
5. The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper tube.
Before using the air conditioner, be sure to check and
preset the following.
1.Remote Control presetting
Each time after the remote control is replaced with new
batteries or is energized, remote control auto presetting
heat pump.If the air conditioner you purchased is a Cool
ing Only one, heat pump remote controiler can also be
used.
2.Back-light function of Remote Control(optional)
Hold down any button on remote control to activate the
back light. It automatically shuts off 3 seconds later.