Split type air conditioner / User Manual 9 / 108 EN
8 / 112 EN
Split Type Air Conditioner / User Manual
wiring in accordance with the
wiring rules.
Take note of fuse
specifications
The air conditioner’s circuit board
(PCB) is designed with a fuse to
provide overcurrent protection.
The specifications of the fuse are
printed on the circuit board, such
as:
T3.15AL/250VAC, T5AL/250VAC,
T3.15A/250VAC, T5A/250VAC,
T20A/250VAC, T30A/250VAC, etc.
C
Note: For the units using
R32 or R290 refrigerant, only
the blast-proof ceramic fuse
can be used.
Warnings for product
installation
1. Installation must be
performed by an authorized
dealer or specialist. Defective
installation can cause water
leakage, electrical shock, or
fire.
2. Installation must be performed
according to the installation
instructions. Improper
installation can cause water
leakage, electrical shock, or
fire.
3. Contact an authorized service
technician for repair or
maintenance of this unit. This
appliance shall be installed
in accordance with national
wiring regulations.
4. Only use the included
accessories, parts, and
specified parts for installation.
Using non-standard parts
can cause water leakage,
electrical shock, fire, and can
cause the unit to fail.
5. Install the unit in a firm
location that can support
the unit’s weight. If the
1 Safety precautions
9 / 112 EN
Split Type Air Conditioner / User Manual
chosen location cannot
support the unit’s weight, or
the installation is not done
properly, the unit may drop
and cause serious injury and
damage.
6. Install drainage piping
according to the instructions
in this manual. Improper
drainage may cause water
damage to your home and
property.
7. For units that have an
auxiliary electric heater, do
not install the unit within
1 meter (3 feet) of any
combustible materials.
8. Do not install the unit in a
location that may be exposed
to combustible gas leaks. If
combustible gas accumulates
around the unit, it may cause
fire.
9. Do not turn on the power until
all work has been completed.
10. When moving or relocating
the air conditioner, consult
experienced service
technicians for disconnection
and reinstallation of the unit.
11. How to install the appliance
to its support, please read
the information for details in
“indoor unit installation” and
“outdoor unit installation”
sections.
Note about fluorinated
gasses (Not applicable to the
unit using R290 Refrigerant)
1. This air-conditioning
unit contains fluorinated
greenhouse gasses. For
specific information on the
type of gas and the amount,
please refer to the relevant
label on the unit itself or
the “User Manual - Product
Fiche“ in the packaging of the
outdoor unit. (European Union
products only).
2. Installation, service,
maintenance and repair of
this unit must be performed
by a certified technician.
3. Product uninstallation and
recycling must be performed
by a certified technician.
4. For equipment that contains
fluorinated greenhouse gases
1 Safety precautions