10 / 108 EN Split type air conditioner / User Manual
10 / 112 EN
Split Type Air Conditioner / User Manual
in quantities of 5 tonnes of
CO2 equivalent or more, but
of less than 50 tonnes of
CO2 equivalent, If the system
has a leak-detection system
installed, it must be checked
for leaks at least every
24 months.
5. When the unit is checked for
leaks, proper record-keeping
of all checks is strongly
recommended.
Warning for Using R32/R290
Refrigerant
• When flammable refrigerant
are employed, appliance shall
be stored in a well -ventilated
area where the room size
corresponds to the room area
as specifiec for operation.
For R32 frigerant models:
Appliance shall be installed,
operated and stored in a room
with a floor area larger than
4m
2
.
For R290 refrigerant models,
appliance shall be installed,
operated and stored in a room
with a floor area larger than:
1 Safety precautions
<=9000Btu/h units: 13m
2
>9000Btu/h and
<=12000Btu/h units: 17m
2
>12000Btu/h and
<=18000Btu/h units: 26m
2
>18000Btu/h and
<=24000Btu/h units: 35m
2
• Reusable mechanical
connectors and flared joints
are not allowed indoors.
(EN Standard Requirements).
• Mechanical connectors used
indoors shall have a rate of
not more than 3g/year at 25%
of the maximum allowable
pressure. When mechanical
connectors are reused indoors,
sealing parts shall be renewed.
When flared joints are reused
indoors, the flare part shall be
re-fabricated. (UL Standard
Requirements)
• When mechanical connectors
are reused indoors, sealing
parts shall be renewed.
When flared joints are reused
indoors, the flare part shall be
re-fabricated. (IEC Standard
Requirements)