Split type air conditioner / User Manual 23 / 108 EN
22 / 112 EN
Split Type Air Conditioner / User Manual
4 Installation
C
If the wall is made of brick,
concrete, or similar material,
drill 5mm-diameter (0.2in-
diameter) holes in the wall
and insert the sleeve anchors
provided. Then secure the
mounting plate to the wall by
tightening the screws directly
into the clip anchors.
Step 3: Drill wall hole for connective piping
1. Determine the location of the wall hole based
on the position of the mounting plate. Refer to
Mounting Plate Dimensions.
2. Using a 65mm (2.5in) or 90mm(3.54in)
(depending on models )core drill, drill a hole in
the wall. Make sure that the hole is drilled at
a slight downward angle, so that the outdoor
end of the hole is lower than the indoor end
by about 5mm to 7mm (0.2-0.275in). This will
ensure proper water drainage.
3. Place the protective wall cuff in the hole. This
protects the edges of the hole and will help
seal it when you finish the installation process.
A
CAUTION! When drilling the wall
hole, make sure to avoid wires,
plumbing, and other sensitive
components.
Wall
Indoor Outdoor
5-7 mm
(0.2-0.275in)
Wall
5-7 mm
(0.2-0.275in)
OutdoorIndoor
4.2.2 Mounting plate dimensions
Different models have different mounting plates.
For the different customization requirements,
the shape of the mounting plate may be slightly
different. But the installation dimensions are the
same for the same size of indoor unit. See Type A
and Type B for example:
Correct orientation of Mounting Plate
Correct orientation of mounting plate
Type A
Type B
Type A Type B
Left rear wall hole
65mm (2.5in)
Right rear wall hole
65mm (2.5in)
Indoor unit
outline
39mm
(1.5in)
39mm
(1.5in)
285mm (11.2in)
47mm
(1.85in)
47mm
(1.85in)
Model A
148mm(5.8in)
45mm(1.7in) 103mm(4.1in)
715mm(28in)
107mm(4.2in)
130mm(5.1in)
237mm(9.3in)
402mm(15.8in)
Model B
230mm(9.1in)
246mm(9.7in)
185mm(7.3in)
139mm(5.5in)
805mm(31.7in)
411mm(16.2in)
Left rear wall hole
65mm (2.5in)
Right rear wall hole
65mm (2.5in)
Indoor unit
outline
39mm
(1.5in)
39mm
(1.5in)
285mm (11.2in)
47mm
(1.85in)
47mm
(1.85in)
45mm(1.7in)
107mm(4.2in)
23 / 112 EN
Split Type Air Conditioner / User Manual
Left rear wall hole
65mm (2.5in)
Right rear wall hole
65mm (2.5in)
Indoor unit
outline
302mm (11.88in)
36mm
(1.4in)
36mm
(1.4in)
47mm
(1.85in)
47mm
(1.85in)
Model C
285mm(11.2in)
243mm(9.57in)
45mm(1.7in)
240mm(9.5in)
143mm(5.6in)
100mm(3.9in)
958.3mm(37.7in)
458mm(18in)
Model D
Left rear wall hole
65mm (2.5in)
Right rear wall hole
65mm (2.5in)
324.9mm (12.79in)
55mm
(2.16in)
47mm
(1.85in)
47mm
(1.85in)
55mm
(2.16in)
264mm(10.4in)
1037.6mm(40.85in)
219mm(8.6in)
344mm(13.5in)
299mm(11.8in)
45mm(1.77in)
45mm(1.77in)
559mm(22in)
C
When the gas side connective
pipe is 16mm(5/8in) or more,
the wall hole should be 90mm
(3.54in).
Step 4: Prepare refrigerant piping
The refrigerant piping is inside an insulating
sleeve attached to the back of the unit. You must
prepare the piping before passing it through the
hole in the wall.
1. Based on the position of the wall hole relative to
the mounting plate, choose the side from which
the piping will exit the unit.
2. If the wall hole is behind the unit, keep the
knock-out panel in place. If the wall hole is to
the side of the indoor unit, remove the plastic
knock-out panel from that side of the unit. This
will create a slot through which your piping
can exit the unit. Use needle nose pliers if the
plastic panel is too difficult to remove by hand.
Knock-out Panel
Knock-out Panel
3. If existing connective piping is already
embedded in the wall, proceed directly to
the Connect Drain Hose step. If there is no
embedded piping, connect the indoor unit’s
refrigerant piping to the connective piping that
will join the indoor and outdoor units. Refer to
the Refrigerant Piping Connection section of
this manual for detailed instructions.
C
Refrigerant piping can exit the
indoor unit from four different
angles: Left-hand side, Right-
hand side, Left rear, Right rear.
A
CAUTION! Be extremely careful
not to dent or damage the
piping while bending them
away from the unit. Any dents in
the piping will affect the unit’s
performance.
Step 5: Connect drain hose
By default, the drain hose is attached to the
lefthand side of unit (when you’re facing the back
of the unit). However, it can also be attached to
the right-hand side. To ensure proper drainage,
attach the drain hose on the same side that your
refrigerant piping exits the unit. Attach drain hose
extension (purchased separately) to the end of
4 Installation