7.7 Man Down
(1) Man Down Trigger Method
This parameter determines the method used to trigger Man Down mode of the radio.
The radio will have real-time detections of its tilt gradient and movement. When it satisfies the conditions of Man Down Trigger Method over the preset Trig
Entry Delay Time, it will enter the Man Down mode automatically. Option:
•Tilt Only: When the radio tilts at or over the preset Trig Tilt Gradient over the Trig Entry Delay Time, it will enter the Man Down mode automatically.
•No Movement Only: When the radio is motionless or takes uniform rectilinear motion (reference object: the ground) over Trig Entry Delay Time, the radio will
enter the Man Down mode automatically.
•Tilt or No Movement: When the radio tilts at or more than Trig Tilt Gradient or is motionless over Trig Entry Delay Time, it will enter the Man Down mode
automatically.
Default: Tilt Only
(2) Trig Tilt Gradient
This parameter decides the tilt gradient to trigger Man Down mode of the radio.
The radio will have real-time detections of its tilt degrees off the vertical. When the radio's degree off the vertical exceeds Tilt Gradient, the radio will enter
Man Down mode automatically.
Option: 75°, 60°, 45°, 30°. Default: 60°
(3) Man Down Delay Time
This parameter allows you to set the amount of time before the radio sends emergency alarm. The radio will not send emergency alarm if it is placed vertically
within the preset duration.
Range :10–255s (0 indicates that the Man Down feature will be enabled immediately when the radio falls down).
Step:1s; Default:10s
Note:This parameter is available only when Man Down is selected.
(4) Man Down Pre-Alert Time
After you Man Down the radio and within Trig Entry Delay Time before the emergency mode is activated, the radio will pre-alert you to the situation. This
parameter is to set the alert time.
Range: 10 – 254seconds (0= the emergency mode would be activated without any pre-alert.). Step :1 second. Default :5 seconds
Note:
•
This parameter is available only when Man Down is selected.
•
The Man Down Pre-Alert Time must be shorter than or equal to Man Down Delay Time.