Wine Merchandiser Refrigerators Wine Merchandiser Refrigerators
Troubleshooting
Problem
Possible Cause
Possible Solution
Compressor
not running.
Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker.
Power cord unplugged. Plug in power cord.
Thermostat set too high. Set thermostat to lower temperature.
Cabinet in defrost cycle. Wait for defrost cycle to finish.
Condensing units run
for long periods of time.
Excessive amount of water product in
cabinet.
Allow adequate time for product to cool down.
Prolonged door opening or door ajar.
Ensure doors are closed when not in use. Avoid
opening the doors for long periods of time.
Dirty condenser coil. Clean the condenser coil.
Evaporator coil iced over.
Unplug unit and allow coil to defrost. Make sure
thermostat is not set too cold. Ensure that door
gasket(s) are sealing properly.
Door gasket not sealing properly.
Ensure gaskets are snapped in completely.
Remove gasket and wash with soap and water.
Check condition of gasket and replace if
necessary.
Cabinet temperature
is too warm.
Thermostat set too warm. Set thermostat to lower temperature.
Airflow blocked.
Re-arrange product to allow for proper airflow.
Make sure there is at least 4" of clearance from
evaporator.
Excessive amount of warm product placed
in cabinet.
Allow adequate time for product to cool down.
Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker.
Dirty condenser coil. Clean the condenser coil.
Evaporator coil iced over.
Ensure doors are closed when not in use.
Avoid opening doors for long periods of time.
Low refrigerant levels.
Contact a service technician to check
refrigerant levels.
Door is slightly ajar. Make sure door is completely closed.
Interior light is
not working.
Poor switch connection. Turn o light switch and turn it back on.
Bulb is not connected.
Make sure the bulb is correctly inserted in
the socket.
Bulb has burned out. Replace the bulb.
Condensation is
collecting on the
cabinet and/or floor.
Relative humidity is above 60%.
Move unit to area below relative humidity or
lower humidity level.