Handleiding
Je bekijkt pagina 8 van 9

8
User Manual
www.AvantcoRefrigeration.com
Wine Merchandiser Refrigerators
Operation / Maintenance
WARNING: DISCONNECT THE POWER CORD BEFORE CLEANING ANY PARTS OF THE UNIT.
NOTE: We strongly recommend that any servicing be performed by an authorized service technician.
Loading Product
• Do not block the air duct/fan at the top of the unit.
• Ensure all shelves are sitting level and properly secured before loading products.
• Do not store flammable and explosive gas or liquids inside the unit.
Cleaning the Fan Blades and Motor
• If necessary, clean the fan blades and motor with a soft cloth.
• If it is necessary to wash the fan blades, cover the fan motor to prevent moisture damage.
Cleaning the Interior of Unit
• When cleaning the cabinet interior, use a solvent of warm water and mild soap.
• Do not use steel wool, caustic soap, abrasive cleaners, or bleach that may damage the interior finish.
• Wash door gaskets on a regular basis, preferably weekly. Simply remove door gasket from the frame of
the door, soak in warm water and soap for thirty (30) minutes, dry with soft cloth, and replace.
• Check door gaskets for proper seal after they are replaced.
• Periodically remove the shelves and pilasters from the unit and clean them with a mild soap and warm
water. To remove the pilasters, first remove the shelves and shelf brackets. Then, simply lift the pilaster
up and out.
Cleaning the Condenser Coil
• For ecient operation, keep the condenser surface free of dust, dirt, and lint.
• We recommend cleaning the condenser coil at least once per month.
A dusty condenser may lead to high energy consumption, less cooling eectiveness, and compressor damage.
CONDENSER COIL CLEANING INSTRUCTIONS
NOTE: The condenser coil is located at the bottom behind the panel.
1. Disconnect the electrical power from the unit.
2. Remove the front cover and base cover with a screwdriver.
3. Using a soft brush and/or vacuum, remove the dirt, lint, etc. from the finned condenser coil in a
vertical direction.
4. Clean the condenser with a commercial condenser coil cleaner, available from any kitchen
equipment retailer (example: Nobel Chemical Tech Line).
5. After cleaning, straighten any bent condenser fins with a fin comb.
6. When finished, be sure to reinstall the front cover and base cover.
7. Reconnect the electrical power to the unit.
Bekijk gratis de handleiding van Avantco GDW-23-BBC, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.