Cleaning
Warning: Before cleaning, always unplug the equipment.
Cabinet Interior Cleaning: Use a solvent of warm water and mild soap.
Avoid Abrasives: Do not use steel wool, caustic soap, abrasive cleaners, or bleach that may damage
the interior finish.
Door Gasket Cleaning: Every 3-6 months, inspect door gaskets and clean as required.
Recommended to be completed by a professional. Worn or dirty gaskets can cause air leaks, reduce
cooling performance and introducing unwanted moisture in the cabinet that can cause the evaporator
coil to freeze.
Door Gasket Cleaning:
- Wash door gasket(s) weekly.
- Remove the gasket(s) from the door frame, soak in warm water and soap for 30 minutes,
dry with a soft cloth, and replace.
- Check the gasket(s) for a proper seal after replacement.
Shelf and Pilaster Cleaning:
- Periodically remove the shelves and pilasters from the unit and clean them with mild soap
and warm water.
- To remove the pilasters, first remove the shelves and shelf brackets, then lift the pilaster up
and out.
Condenser Coil Cleaning:
Note: This is required to be completed by a qualified and insured food service technician.
Important Information:
- Dust Risks: A dusty condenser may lead to high energy consumption, less cooling effectiveness,
and compressor damage.
- Regular Maintenance: For efficient operation, keep the condenser surface free of dust, dirt, and lint.
- Monthly Cleaning: We recommend cleaning the condenser coil at least once per month
- Location Note: The condenser coil is located at the bottom behind the panel.
Cleaning Instructions:
1. Disconnect Power: Disconnect the electrical power from the unit.
2. Remove Covers: Remove the front cover and base cover with a screwdriver.
3. Clean Debris: Using a brush and/or vacuum, remove the dirt, lint, etc. from the finned condenser
coil in a vertical direction.
4. Apply Cleaner: Clean the condenser with a commercial condenser coil cleaner, available from
any kitchen equipment retailer. Ex. Noble Chemical Tech Line Coil Cleaners (147TLECCLNR,
148TLHDCCLNR, 148TLECOILDD, 148TLFMCCLNR, 147TLEVPCLNR, or 147TLHDCCLNR).
5. Straighten Fins: After cleaning, straighten any bent condenser fins with a fin comb.
6. Replace Covers: When finished, be sure to reinstall the front cover and base cover.
7. Restore Power: Reconnect the electrical power to the unit.