When test pressures exceed ½ PSI (3.45 kPa), the vertical broiler and its individual shuto valve must be
disconnected from the gas supply piping system.
An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas
necessary for satisfactory performance. The gas valve and convertible pressure regulator, which is provided
and preset at the factory, is set to maintain a 4" W.C. manifold pressure for natural gas or 10.0" W.C. manifold
pressure for propane gas. However, to maintain these conditions the pressure on the supply line, when all
units are operating simultaneously, should not drop below 7" W.C. for natural gas or 11" W.C. for propane
gas.
Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems and aect burner
operating characteristics.
When test pressures are ½ PSI (3.45 kPa) or less, the vertical broiler must be isolated from the gas supply
piping system by closing its individual shuto valve.
NOTICES:
Purge the supply line to clean out dust, dirt, or other foreign matter before connecting the line to the unit.
Use pipe joint compound that is suitable for use with both natural and LP gas on all threaded connections.
Check the level of the vertical broiler by placing a level on top of the vertical broiler after gas connections
have been made.
New units are wiped down at the factory to remove any visible signs of dirt, oil, grease, etc. remaining from
the manufacturing process.
Before any food preparation, thoroughly wash the protective oil from all surface parts and the tank interior
with hot soapy water to remove any film residue and dust or debris.
Wash any accessories shipped with unit.
Rinse vertical broiler and accessories thoroughly.
Wipe machine completely dry with a soft, clean cloth.
Check the level of the vertical broiler by placing a level on top of the vertical broiler after gas connections
have been made.
NOTICE:
Do not use chlorine or sulfate/sulfide cleaners.
Installation (Continued)
Before First Use
Testing the Gas Supply Piping System
Leveling the Vertical Broiler
Cleaning

Bekijk gratis de handleiding van Avantco 177VB204, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkAvantco
Model177VB204
CategorieNiet gecategoriseerd
TaalNederlands
Grootte2064 MB