www.AvantcoEquipment.com
Visually check all inlet pipes supplied by the installer and/ or blow them out using compressed
air to clean out any dirt or debris (threads or other foreign matter) before installing a service
line. These particles will clog the gas holes when gas pressure is applied. Compounds used
in appliance pipe threaded joints shall be resistant to the action of GN and LPG gas and shall
provide a gas tight seal to prevent leakage.
When installing the pressure regulator remember that it can support 1/2 PSI (3.45kPa).
When installing LPG, you have high source pressures ranging from 20 PSI (127.89kPa) to 100 PSI
(689.48 kPa). If the LPG tank’s high pressure gas line is directly connected to a unit without the
proper reduction regulator, it will rupture the diaphragm in the valve, making it useless.
Any adjustment to the regulator should be done only by qualified and licensed personnel with
the appropriate calibrated test equipment.
Connections must be made my a licensed and qualified contractor.
IMPORTANT
The products are produced for the use of natural gas (NG). Then check if the gas used in your
region is compatible with the type of gas for which the product was manufactured. Otherwise,
the product must be converted to be used in propane gas (LPG).
Gas Conversion Instructions
!
After converting the product gas, the,
pressure regulator must be converted
by inverting the fitting under the
regulator cover. This will require a
reasonable, amount of force. Do not
remove the spring. When replacing
the cover, make sure the insert of the
socket is facing upwards in the middle
of the spring. As shown in the image
on the side.
Then re-attach the pressure regulator
to the gas inlet of the product and
apply the “Warning” sticker for the gas
to be used on the front of the unit for
future reference.
!
IMPORTANT
TO PERFORM GAS CONVERSION, A LICENSED AND QUALIFIED
TECHNICIAN IS REQUIRED.