VK211 User Manual
11
duration: press and hold for the specified duration (ms).
interval: time interval between each key (ms). The maximum is 500ms.
Acknowledge:
Command OK: Command is correct and the function is executed.
Command incorrect: Unavailable command or parameters.
Example:
io p01 k 01: Save the action of pressing keycode 01 once to port 1.
io p01 k 01,A0,A5,81,84: Save the action of pressing keycodes 01, A0,
A5, 81, and 84 once to port 1.
io p02 k 01+A0+A5: Save the action of pressing 01, A0, and A5 together,
and then releasing them simultaneously to port 2.
io p01 k 01+A0+A5 fdfu: Save the action of pressing 01, A0, and A5
together, and releasing keycode 01 first to port 1.
io p01 k 01 d 1000: Save the action of pressing and holding 01 for 1000
ms to port 1.
io p01 t 300: Set the time interval between key pressing to 300 ms.
Echo
Usage: To show keyboard inputs (performed at the local console) on the
remote console through RS-232 serial communication.
Syntax:
echo <control>
Parameter:
control:
on: to enable the function
off: to disable the function. This is the default setting.
Response:
Each response is shown as follows, where xx is a corresponding keycode
of the pressed key:
keypress xx
keypress 00
Acknowledge:
Command OK: Command is correct and the function is executed.