T12 Tube Mic Preamp API Select
4
2.0 Quick Start
One tip to get started: We try to design all of our processing modules with the understanding that
there is never enough time to read a manual and learn all of the features in the 10 seconds that is
allowed during a setup. If you simply set all of the parameters as follows the T12 will have a useful,
but conservative effect on the signal.
After the unit has been powered on and warmed up*:
Connect a microphone to the INPUT XLR on the rear panel
Set MIC IMPEDANCE to 1500 OHMS
Set LOW CUT to OUT
Set GAIN to the fully counter-clockwise position
Set LEVEL to the fully clockwise position
Disengage the POL (polarity inverter) switch
Engage the 48V switch if a phantom-powered microphone is connected**
Engage the MIC switch to select the XLR microphone INPUT on the rear panel
Adjust the GAIN control to set the desired level
These settings will provide a good starting place for additional tweaking to achieve the desired sound.
*NOTE: The T12 is a tube-based processor that requires 15 minutes for the tubes to warm-up
to a stable temperature before tonal qualities become consistent.
**NOTE: CAUTION! Only engage the 48V switch when microphones that require 48-volt
phantom power are connected. Phantom power will damage many ribbon mics,
especially vintage ribbon mics, so use great care when engaging 48V phantom power.
**NOTE: CAUTION! Never connect or disconnect microphones when 48-volt phantom power
(48V) is engaged. Wait 5-10 seconds after the 48V switch is disengaged for the circuit
to discharge before disconnecting microphones.