Handleiding
Je bekijkt pagina 18 van 24

18
2
1
5
3
1
4
3
1
SWAPPING PROCEDURE:
- Unscrew and remove the two screws (3) holding the lens bracket (4)
CAUTION: the lens bracket is integrated electronic parts
- Disconnect the connector between the lens and the lens bracket (4)
- Unscrew and remove the three 120° screws (1) holding the engraved focus ring (2)
- Pull out the engraved focus ring (2)
- Replace the new engraved focus ring (2) for feet or meter use and put the three screws (1) in contact
- Re-connect the connector to the lens bracket
- Tighten the two screws (3) on the lens bracket (4)
- Check and adjust the focus ring position to match the engraved distances and tighten uniformly the three screws (1)
- Tighten all the screws in contact with a removable threadlock
Bekijk gratis de handleiding van Angénieux Optimo Ultra Compact 21-56, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Angénieux |
| Model | Optimo Ultra Compact 21-56 |
| Categorie | Lens |
| Taal | Nederlands |
| Grootte | 6166 MB |