TORQUE SETTINGS FOR SCREWS
TORQUE DRIVERS (Recommended): UTICA TS-30 (Shown)
TORQUE DRIVER (Alternate):
• Proto J6107A
• Wiha 28887
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE
ISSUES! TO CONFIRM THE IP65 INTEGRITY AFTER A LAMP REPLACEMENT,
TEST THE FIXTURE USING THE IP TESTER. CONTACT ADJ SERVICE FOR
MORE DETAILS.
IP PRESSURE TESTING PARAMETERS
Maximum Pressure Minimum Pressure Steady/Hold Time
3.3 psi
(23 KPa)
2.9 psi
(20 KPa)
15 sec
CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS
STRONGLY RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST!
AVOID PLACING YOUR FACE, EYES, HANDS, ETC IN CLOSE PROXIMITY TO
THE FIXTURE’S LENS WHILE PERFORMING THE TEST!