American DJ Hydro Beam X1 handleiding

42 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 17 van 42
17
TORQUE SETTINGS
TORQUE DRIVERS (Recommended):
UTICA TS-30 (Shown)
ALTERNATIVE DRIVERS:
Proto J6107A
Wiha 28887
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE IS-
SUES! TO CONFIRM THE IP65 INTEGRITY AFTER A LAMP REPLACEMENT, TEST
THE FIXTURE USING THE ELATION IP TESTER. CONTACT ADJ SERVICE FOR
MORE DETAILS.
CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS
STRONGLY RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST!
AVOID PLACING YOUR FACE, EYES, HANDS, ETC IN CLOSE PROXIMITY TO THE
FIXTURE’S LENS WHILE PERFORMING THE TEST!
IP PRESSURE TESTING PARAMETERS
Low Pressure Limit High Pressure Limit Steady/Hold Time
2.9 psi
(20 KPa)
3.3 psi
(23 KPa)
15 sec

Bekijk gratis de handleiding van American DJ Hydro Beam X1, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkAmerican DJ
ModelHydro Beam X1
CategorieNiet gecategoriseerd
TaalNederlands
Grootte6603 MB