DMX SET UP
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of commu-
nication between intelligent xtures and controllers. A DMX controller sends DMX data instructions
from the controller to the xture. DMX data is sent as serial data that travels from xture to xture
via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX xtures (most controllers only
have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufacturers to be
linked together and operate from a single controller, as long as all xtures and the controller are DMX
compliant. To ensure proper DMX data transmission, try to use the shortest path possible when link-
ing several DMX xtures. The order in which xtures are connected in a DMX line does not inuence
the DMX addressing. For example, a xture assigned a DMX address of 1 may be placed anywhere
in a DMX line: at the beginning, at the end, or anywhere in the middle. When a xture is assigned a
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no
matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation): The Encore Burst RGBW IP can
be controlled via DMX-512 protocol. The Encore Burst RGBW IP has multiple DMX channel modes.
Your unit and your DMX controller requires a 5-pin XLR connector for data input and data output. We
recommend Accu-Cable DMX cables. If you are making your own cables, be sure to use standard
110-120 Ohm shielded cable (This cable may be purchased at almost all pro lighting stores). Your
cables should be made with a male XLR connector on one end and a female XLR connector on the
other. Also remember that DMX cable must be daisy chained and cannot be split.
Special Note: Line Termination. When longer runs of cable are used, you may need to use a ter-
minator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor
which is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is
inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a
cable terminator (ADJ part number Z-DMX/T) will decrease the chance of erratic behavior.
TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING THE FIX-
TURE, ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED AND ONLY IP65 RATED
POWER AND DATA CABLES MAY BE USED.