- 46 -
ON
OFF
SW1
1 2 3
4
1
DIP switches
1 SW1
No. Function Default
1
Sets the night illumination.
ON: Always off
OFF: Turns on/off automatically
OFF
2
Sets whether surveillance camera or light is
attached.
ON: Surveillance camera
OFF: Light control
OFF
3 to 4
Sets the display mode at the beginning of a
call.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
3 4 3 4
3 4
3 4
3: OFF
4: OFF
(Zoom)
Camera module (GT-VB)
Positions of switch 3 and 4
Zoom
Wide (3 seconds)
Zoom
Wide
ON
OFF
1
SW1
1 2 3
4
5 6 7
8
DIP switches
Entrance station (all-in-one type)
GT-DMB-LVN, GT-DMB-N
1 SW1
No. Function Default
1
Sets this entrance station as used for either a
multi building system or single building
system.
ON: Multi building system
OFF: Single building system
OFF
2 to 4
Sets the ID of this entrance station.
*
(9) - (16): GT-BCXB-N Common trunk line 2
2
(10)
3
(11)
5
(13)
8
(16)
4
(12)
7
(15)
6
(14)
1
(9)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
2 3 4 234 234
234 234
234234 234
2: OFF
3: OFF
4: OFF
(ID 1)
7
Sets the event that triggers LCD.
ON
OFF
ON
OFF
7 7
OFF
(Sensor
detection)
8
Resets the passcode for the installer or
administrator when this unit is initialized by
setting this switch to ON in 2 seconds.
OFF
ID number
Positions of
switch 2 to 4
Sensor detection
Operation of this unit
Zoom (3 seconds) Wide
: Do not change these switches.

Bekijk gratis de handleiding van Aiphone GF-3B, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkAiphone
ModelGF-3B
CategorieNiet gecategoriseerd
TaalNederlands
Grootte9766 MB

Caratteristiche Prodotto

Kleur van het productZwart
Aantal per verpakking1 stuk(s)
MerkcompatibiliteitAiphone
Stroomverbruik- mA
Type productInbouwdoos