• Setting a zone in power level
Once your product is on, simply press the Mode button until the display shows Po, the P
indicator light comes on, then use the + / - selection buttons to adjust the power level. The
values flash until the heating zone reaches the required power.
Your device can deliver a maximum total power of 3000W. Each zone can deliver this
maximum power when the second fireplace is off. If the 2 cooking zones are on, the sum of the
powers of the 2 cooking zones cannot exceed 3000W. If you have lit a zone with a certain
power and you want to light the second on a power that would exceed the total power of
3000W, in this case the power of the first zone will go down automatically and the maximum
power will always be the same.
Examples :
- Left zone off ; maximum power on right zone = 3000W
- Right zone = 1500W ; maximum power on left zone = 1500W
- Right zone = 2300W ; maximum power on left zone = 700W
- Left zone = 2500W ; requested power on right zone = 2000W ; left zone will go down to
1000W
Power level Power in watts
1 100
2 200
3 300
4 400
5 500
6 600
7 700
8 800
9 900
10 1000
11 1100
12 1200
13 1300
14 1400
15 1500
Each power level corresponds to a step of 100W.
Power level Power in watts
16 1600
17 1700
18 1800
19 1900
20 2000
21 2100
22 2200
23 2300
24 2400
25 2500
26 2600
27 2700
28 2800
29 2900
30 3000