9 WISE-S100 Series User Manual
Chapter 3 Hardware Specification
3.6 Cable Wiring and Ping Assignment
The cable of the WISE-S100 stack light sensor is connected and installed in default
package. The power input of the sensor is 3.3~30VDC.
Please refer to the pin assignment via below table.
Figure 3.1 WISE-S100 Connector Pin Assignment
Table 3.1: WISE-S100 Cable Definition
2M Cable with Wafer Box
PN:1700031410-01
1 Red V+ In
2 Black GND
3 Brown DATA+
4 Yellow MCU Interrupt
5 Orange DATA-
6 Green IO Interrupt