WISE-S100 Series User Manual 8
3.1 Power
Power Supply: 3.3~30 VDC
Power Consumption: 15 mA
3.2 Generic
Communication Interface: RS-485 (Modbus/RTU)
Baud Rate: 9600,N,8,1
3.3 Ambient Light Sensor
Number of Sensor: 8
Sensor Detection Rate: 3 Hz
Measuring Range: 20.48~83865.6 lux
Measuring Light Status: On, Off, Slow Blink, Fast Blink
Peak Irradiance: 550 nm (TYP.)
Spectral Responsivity:
Resolution: 12 bits
Accuracy*: 15%
*Accuracy of measurement of fluorescent light.
Linearity
Input illuminance: > 40 lux, 2% (TYP.)
Input illuminance: < 40 lux, 5% (TYP.)
Temperature Drift: 0.02%/°C
3.4 Mechanical
Dimension (L x W x H): 220 x 14 x 12.8 (mm)
Material: Polycarbonate (PC)
3.5 Environmental
Operating Temperature: -25~70 °C
Storage Temperature: -40~80 °C
Operating Humidity: 5~95% RH
Storage Humidity: 0~95% RH