USB-4716 User Manual 12
3.4 Analog Output Connections (Voltage)
USB-4716 provides two analog output channels, AO0 and AO1. Figure 3.4 shows
how to make analog output connections on USB-4716.
Figure 3.4 Analog Output Channel Connections
3.5 Trigger Source Connections
3.5.1 Internal Pacer Trigger Connection
USB-4716 provides two 16-bit counters connected to a 10 MHz clock. Counter 0 is a
counter that counts events from an input channel. Counter 1 is a 16-bit timer for
pacer triggering. A low-to-high edge from the Counter 1 output will trigger an A/D
conversion on USB-4716.
3.5.2 External Trigger Source Connection
In addition to pacer triggering, USB-4716 also allows external triggering for A/D con-
versions. When GATE is connected to a +5V DC source, the external trigger function
is thereby disabled. The external trigger function will be enabled once the +5V DC
source is removed.