Advantech PCL-833 handleiding

28 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 17 van 28
9 PCL-833 User Manual
Chapter 2 Installation & Jumpers
Table: Card I/O Address (SW1)
X = Off, O = On, * = Default
2.3.2 Interrupt level (JP1)
The jumper JP1 selects the card's interrupt level (2, 4, 5, 7, 10, 11, 12, 15) as shown
below:
Card interrupt (default = 7)
Do not select a level that is being used by another device unless you have performed
special programming to share several devices on one interrupt.
To use the interrupt you must install an interrupt service routine and program the
PCL-833's on-board the 8259 interrupt controller.
Nine different conditions can enable the PCL-833's interrupt, but only one at a time.
Bit 3 of register BASE+9 switches interrupt source 7 between the card's TIMER and
Dl1. See Chapter 3 for details.
You should treat all the interrupt sources as positive-edge triggered when you pro-
gram the 8259.
Range (hex) Switch Position
123456
200 - 20F(*) XOOOOO
210 - 21F XOOOOX
220 - 22F XOOOXO
230 - 23F XOOOXX
240 - 24F XOOXOO
………………
3F0 - 3FF XXXXXX
Interrupt
Source
Condition
0 CH1 overflow
1 CH2 overflow
2 CH3 overflow
3CH1 ZIN
4CH2 ZIN
5CH3 ZIN
6DI0
7 Shared by TIMER and DI1

Bekijk gratis de handleiding van Advantech PCL-833, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkAdvantech
ModelPCL-833
CategorieNiet gecategoriseerd
TaalNederlands
Grootte1770 MB