2. Reboot the device.
3. Enable temperature threshold and configure the alarm when the temperature exceeds
30°C.
4. Disable mutation threshold and configure the alarm when the mutation value exceeds 5°C.
5.4 Historical Data Enquiry
LEO-S592-TPG0 supports sending downlink commands to enquire historical data for
specified time point or time range. Before that, ensure the device time is correct and data
storage feature was enabled to store the data.
Command format:
Channel
Type
Description
fd
6b (Enquire data in time point)
4 Bytes, unix timestamp
fd
6c (Enquire data in time range)
Start time (4 bytes) + End time (4 bytes),
Unix timestamp
fd
6d (Stop query data report)
ff
ff
6a (Report Interval)
3 Bytes,
Byte 1: 01
Byte 2: interval time, unit: s,
ff10ff
Channel
Type
Value
ff
10 (Reboot)
ff (Reserved)
ff06 ca 0000 2c01 00000000
Channel
Type
Value
ff
06 (Set Threshold Alarm)
CTRL: ca =11 001 010
010 = above
001 = Temperature Threshold
1 = enable the Threshold Alarm
Max: 2c 01 => 01 2c => 300*0.1 = 30°C
ff06 10 0000 3200 00000000
Channel
Type
Value
ff
06(Set Threshold Alarm)
CTRL: 10 = 00 010 000
010 = Temperature Mutation Threshold
0 = disable the Threshold Alarm
Max: 32 00 => 00 32 => 50*0.1 = 5°C