Appendix A LCD Optical Characteristics
Note(4): Measurement method
The LCD module should be stabilized at given temperature for 30 minutes to avoid
abrupt temperature change during measuring. In order to stabilize the luminance, the
measurement should be executed after lighting Backlight for 30 minutes in a stable,
windless and dark room. Optical Equipment: DT-100, or equivalent
Note(5): Definition of response time
The output signals of the photo detector are measured when the input signals are
changed from "Full Black" to "Full White" (rising time), and from "Full White" to "Full
Black "(falling time), respectively. The response time is an interval between 10% and
90% of amplitudes. Please refer to the figure below.
Minimum Bri
g
htness of nine points
W9
=
Maximum Bri
g
htness of nine points
100
90
10
0
%
Optical
response
White Black White
Tf Tr
90
10
0
Optical
response
White Black White
Tr