Advantech ICR-2413 handleiding

44 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 25 van 44
ICR-2412
2.6 Serial Interfaces
The pins of RS232 and RS485 serial interfaces are physically connected to the 7-pin ter-
minal block panel socket located on the left panel. The pinout of this connector is described in
Figure 18 and in Table 8, resp. Table 9.
Figure 18: RS485 and RS232 Pinout
Pin Signal mark Description
1 D (+) In/Out
2 D (-) In/Out
3 GND Ground (common with RS232)
Table 8: Connection of RS485
Pin Signal mark Description
3 GND Ground (common with RS485)
4 RXD Received Data
5 TXD Transmit Data
6 RTS Request to Send
7 CTS Clear to Send
Table 9: Connection of RS232
The serial interfaces are not eletrically isolated from the router.