If you're using Windows OS as your working PC, one common tool is PuTTY. Follow the steps below to
establish a connection using PuTTY.
If you're unfamiliar with PuTTY or haven't installed it yet, you can download it from https://www.putty.org/.
If you intend to use PuTTY on a PC running Windows OS. The following of this section describes how to
configure PuTTY on a Windows platform for connection with the FWA-1214 serial console as a reference.
Otherwise, feel free to skip these steps if you have another preferred method. Other terminal programs may
be used in a similar way as well.
Open PuTTY and start the configuration as outlined below. Instead of "COMx", use the actual COM port
number from your client machine. The "COMx" designation will vary based on what you observe in your
Windows Device Manager (Figure 2.4-4).
In this guide, we're using "COM1" as an example, which you might see listed in the Device Manager.
Figure 2.4-4 Windows Device Management COM Number Example
A. Under "serial line", specify "COM1" and set the speed to "115200". Select "no parity" and "no flow
control". The default baud rate for the COM port is 115200 with no parity and no flow control.
B. If you have previously modified these settings, please use the baud rate you configured in the BIOS,
please reference “Common BIOS User Manual (Section 1.2.2.1)”. It's worth noting that the BIOS
and OS might have different serial console configurations.
C. To ensure a smooth installation process, verify that both the BIOS and OS have the same serial
Bekijk gratis de handleiding van Advantech FWA-1214, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.