3.3.1. Module Power-on
3.3.1.1. Power-on Circuit
When the FCPO# (FULL_CARD_POWER_OFF#) pin and reset (RESET#) pin are floating or
connect to an external 3.3V/1.8V, the module will boot up. When AP (Application Processor)
controls the module start-up, it is recommended that the FULL_CARD_POWER_OFF# and
RESET# GPIO port should use a port with low level for reset or internal pull down and the
external pull-down resistance should be reserved. The circuit design is shown in Figure 3-4:
Figure 3-4 Circuit for module start-up controlled by AP
3.3.1.2. Power-on Timing
When power supply is ready, the PMU of module will power on and start initialization process
by pulling high both FCPO# (Pin6) and RESET# (Pin67) signal. After about 30s, the
initialization process of the module will be completed. The power-on timing is shown in Figure
3-5:
Figure 3-5 Power-on timing