Advantech AIW-356 handleiding
Handleiding
Je bekijkt pagina 29 van 65

29
3.3. Control Signals
The AIW-356 DQ-N01 module provides two control signals for power-on/off and reset
operations, the pins are defined in the following table:
Pin
Pin Name
I/O
Reset
Value
Description
Type
6
FULL_CARD_POWER_OFF#
I
PU
Module power-on/off control
3.3V/
1.8V
Pulled up through internal
390KΩ resistor
Power-on: High/Floating
Power-off: Low
67
RESET#
I
PU
Module reset, pulled up
3.3V/
1.8V
through internal
390KΩresistor, active low
50
RESET#
I
PU
Module PCIe interface reset.
3.3V/
1.8V
Active low, Pulled up through
internal4.7KΩ resistor
Table 3-7 Module power-on/off and reset
Note:
RESET # and PERST # need to be controlled by independent GPIO which cannot be shared with
other devices on the host. RESET # and PERST # are sensitive signals. During PCB layout, keep
these signals far away from radio frequency interference. PCB routes must be protected using
GND and kept away from edges of PCBs to avoid module reset due to ESD problems.
Bekijk gratis de handleiding van Advantech AIW-356, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Advantech |
Model | AIW-356 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 8839 MB |