American DJ® - www.americandj.com - Vizi Spot 5R Instruction Manual Page 33 American DJ® - www.americandj.com - Vizi Spot 5R Instruction Manual Page 34
Vizi Spot 5R System Menu
settings of Auto, High, or Low. The default setting is Low.
1. Access the main menu by pressing MODE/ESC button.
2. Tap the UP button until “FANS” is displayed, press ENTER.
3. Press the UP or DOWN buttons to select either “AUTO”,
HIGH” or “LOW”.
4. Press ENTER to conrm your selection.
5. Press MODE/ESC to return to the main menu.
HIBE - With this function you can make the unit auto-
matically shut down the lamp and stepping motors. The
default setting for this is 15 mins. After 15 mins if the unit
is not receiving a DMX signal, the unit will automatically
shut down the lamp and motors. This feature lengthens
the life of the lamp and motors. The shut down time can be
adjusted between OFF (no shut down) or 1 - 99 minutes.
Once the lamp and motors are shut down, it will reset itself
when it receives a DMX signal. When the function is set to
OFF, the lamp and motors will not shut down until power is
cut.
1. Access the main menu by pressing MODE/ESC button.
2. Tap the UP button until “HIBE” is displayed, press ENTER.
3. Press the UP or DOWN buttons to adjust the shut down time.
4. Press ENTER to conrm your selection.
5. Press MODE/ESC to return to the main menu.
VER - Use this function to display the Software version of
the unit.
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
Vizi Spot 5R System Menu
3. Tap the UP button until “VER” is displayed, press ENTER.
4. The display will show “V-X.X”, “X.X” stands for the version
number, such as the display may show “V-1.0”, “V-9.9” etc.
5. Press ENTER or MODE/ESC to exit.
ADJU - Use this function is used to make sure all motors
are aligned and to adjust any motors that are not.
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “ADJU” is displayed, press ENTER.
4. Tap the UP button until “CODE” is displayed, press ENTER.
5. The display will show “CXXX”, were as “XXX” represents the
calibration password. The calibration password is “C050.” Use
the UP or DOWN buttons to enter the proper password.
6. Once the proper password is entered the display will read
CHXX”, were as “XX” represents the xture channel number.
7. Select the desired channel to be calibrated by pressing the
UP or DOWN buttons and then ENTER to conrm.
8. The display will then read “XXXX”, were “XXXX” stands for
the calibrate values.
9. Adjust the desired calibration value between –128 and 127
by pressing the UP and DOWN. As you scroll up and down
through the calibration values you will notice slight changes in
the wheel or motor you are attempting to calibrate.
10. Once you reach your desired calibration press ENTER to
conrm and lock in your calibration.
11. Once you are completely nished press MODE/ESC to
return to the main menu.