From there you can adjust the address, using your DMX Con-
toller. First make sure all channels are set to the value of “0”.
1. On your DMX controller set the DMX value of Channel 1 to
the value “7”.
2. Now set the DMX value of Channel 2 to the value “7” to
adjust the starting address between 1 and 255. To adjust the
address between 256 and 511 set Channel 2 to the value “8” .
3. Set the DMX value of Channel 3 to your desired start-
ing address. This will take about 20 seconds before the unit
accepts the new DMX address.
EXAMPLE: If you want the address to be 57, you must rst set
the address that is currently assingned to the unit. The proceed
to set Channel 1s’ value to “7”, Channel 2s’ value to “7”, and
Channel 3s’ value to “57”.
2ND EXAMPLE: If you want the address to be 420, you must
rst set the address that is currently assingned to the unit.If you
want the set the address to 420, set Channel 1s’ value to “7”,
Channel 2s’ value to “8”, and Channel 3s to “164”. (256 + 164 =
420)
DLOF - With this function you can adjust the lamp via
the control board. The shutter opens and the lamp can be
adjusted. In this mode, the device will not react to any con-
trol signal.
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “SPOT” is displayed, press ENTER.
4. The display will show “ON/OFF”.
5. Press the UP button to select “ON” to activate this function,
or “OFF” to deactivate this function.
Vizi Spot 5R System Menu
American DJ® - www.americandj.com - Vizi Spot 5R Instruction Manual Page 30American DJ® - www.americandj.com - Vizi Spot 5R Instruction Manual Page 29
6. Press MODE/ESC to return to the main menu.
SPEC MAIN MENU -
LAAU With this function the lamp will ignite when power
is applied. By default the unit will automatically ingnite
when power is applied. Use this function to disable that
feature.
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “LAAU” is displayed, press ENTER.
4. The display will show “ON/OFF”. Press the UP button to
select “ON” to switch on the lamp, or “OFF” to switch o the
lamp.
5. Press ENTER to conrm.
6. Press MODE/ESC to return to the main menu.
RDMX With this function you are able to change the DMX
address via any DMX controller. This function is factory set
to “ON” already.
1. Access the main menu by pressing MODE/ESC.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “RDNI I” is displayed, press ENTER.
4. The display will show “ON/OFF”. Press the UP button to
select “ON” to activate this function, or “OFF” to deactivate.
5. Press ENTER to conrm, and “PASS” will ash quickly.
6. Press MODE/ESC to return to the main menu.
To use this function follow the instructions:
To adjust the address of your unit you must rst go to the
address that it is currently set to using your DMX Contoller.
Vizi Spot 5R System Menu