Adj Vizi Q Wash7 handleiding

41 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 25 van 41
Vizi Q Wash7 System Menu
Movement Speed - With this function you can set the pan and tilt movement speed.
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons so
that “Function” is highlighted, then press ENTER.
2. Press the LEFT or RIGHT buttons until “Status” is displayed, press ENTER.
3. Press LEFT or RIGHT buttons, until “Move. Speed” is displayed, and press ENTER.
4. Either “Speed 1”, “Speed 2”, Speed 3or Speed 4” will be displayed, use the LEFT
or RIGHT buttons to toggle between.
5. Press ENTER to conrm your selection or press MODE to exit.
Stand By - With this function the LEDs and step motors will power off if there is no DMX
signal within 15-mins. (factory default). Once it receives a DMX signal, the xture will
reset itself.
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons so
that “Function” is highlighted, then press ENTER.
2. Press the LEFT or RIGHT buttons until “Status” is displayed, press ENTER.
3. Press LEFT or RIGHT buttons, until “Stand By” is displayed, and press ENTER.
4. The current stand by setting will be displayed, use the LEFT or RIGHT buttons to
adjust the hibernation period between 01M-99M or “Off”.
5. Press ENTER to conrm your selection or press MODE to exit.
Fixture ID
Password - With this function you can enter the RDM password so that you can access
and change the RDM ID number.
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons so
that “Function” is highlighted, then press ENTER.
2. Press the LEFT or RIGHT buttons until “Fixture ID” is displayed, press ENTER.
3. Press the LEFT or RIGHT buttons until “ServicePIN” is displayed, press ENTER.
4. The “Password” is 050.
5. Press ENTER or press MODE to exit.
RDM PID - RDM stands for “Remote Device Management”. This feature lets you control
every aspect of your xture remotely from an RDM controller. Manual settings like
adjusting the DMX address are no longer needed. This is especially useful when the unit
is installed in a remote area. In this sub-menu you can see the units RDM ID number and
adjust it as well.
1. Press the MODE button to access the main menu. Press the UP or DOWN buttons so
that “Function” is highlighted, then press ENTER.
2. Press the LEFT or RIGHT buttons until “Fixture ID” is displayed, press ENTER.
3. Press LEFT or RIGHT until “RDM PID” is displayed, and press ENTER.
4. XXXXXX” will be displayed. “XXXXXX” represents the units current RDM ID.
5. Press ENTER or press MODE to exit.
ADJ Products, LLC — www.adj.com — Vizi Q Wash7 — Page 25

Bekijk gratis de handleiding van Adj Vizi Q Wash7, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkAdj
ModelVizi Q Wash7