ADJ Products, LLC - www.adj.com - Focus Spot Two Instruction Manual Page 30 ADJ Products, LLC - www.adj.com - Focus Spot Two Instruction Manual Page 31
Screw
Scr e w
Focus Spot Two Removing the Head Casing
1. Unscrew the single screw 2. Flip the top cover back
3. Remove the lens
4. Unscrew the 4 screws
located on the other side
The gobo’s in this unit are interchangable. Please be very care-
ful when replacing the gobo.
Caution! Never open the unit when in use. Always disconnect
the main power before attempting to change the gobos.
1. To change a gobo, rotate the moving head so that the UV
lens is located on top. Unscrew the single middle screw. See
instruction number 1 on the next page.
2. Once you loosen the single screw you are able to swing the
head back. See instruction number 2 on the next page. You
will now be able to access the gobo wheel. Turn the wheel
with your hand until you come across the gobo you would
like to change.
3. To remove the gobo holder gently pull the gobo holder to-
wards the front of the unit and slide it up and out.
4. Gently and carefully remove the retainer ring. After the re-
tainer ring is removed, carefully remove the gobo.
5. Change the gobo and replace the retainer ring. Carefully slide
the gobo holder back into the housing slot.
6. Reassemble the unit.
Focus Spot Two Changing the Gobo