CAUTION! THE USE OF PROTECTIVE
GLOVES AND SAFETY GOGGLES IS
STRONGLY RECOMMENDED WHILE
PERFORMING THE IP PRESSURE TEST!
AVOID PLACING YOUR FACE, EYES,
HANDS, ETC IN CLOSE PROXIMITY
TO THE FIXTURE’S LENS WHILE
PERFORMING THE TEST!
IP PRESSURE TESTING PARAMETERS
Vacuum
Target Value
Vacuum Test
Minimum
Hold Time
Pressure
Target Value
Pressure
Value
Minimum
-40 KPa
(-5.8 psi)
-35KPa
(-5.1 psi)
30 sec
35 KPa
(5.1 psi)
25 KPa
(3.6 psi)
Following any repair or maintenance procedure that requires disassembly of the device, use Elation’s
IP Tester to confirm the IP integrity of the fixture. The air valve is located on theside of the device next
to the antenna ports, as shown in the diagram below. Please contact ADJ Service for information
regarding the Elation IP Tester, or visit the product information page online at:
https://www.elationlighting.com/ip-tester
DE-HUMIDIFICATION: IP65 fixtures operating in high-humidity environments may experience
residual fogging or condensation. Such fogging will not damage the fixture, and can be removed
using the following procedure: position the unit with the air valve pointing upwards, then open the air
valve and run the unit for 1-2 hours after reaching operating temperature. Then, while the fixture is
still hot, re-install the air valve and allow the unit to cool down. Please note that this procedure should
be performed in a dry, air-conditioned environment. Avoid additional fogging by drying the fixture
completely before placing into a road case.
IP TEST PARAMETERS
Air
Valve